VariTrans P 43000 D2 with Selectable AC/DC Current Ranges
Direct connected AC/DC Current Transducers for High Voltage Systems with 2.2kV AC/DC Isolation.
The Knick VariTrans P 43000 D2 Direct connected AC/DC Current Input Transducers have been designed for use on high voltage DC systems. The isolation system meets the requirements of EN61010-1 with 2.2kV AC/DC and protection against electric shock with protective separation to EN 61140. The rated isolation voltages also meet the requirements of EN 50124-1 this European Standard deals with insulation coordination in railways. It applies to equipment for use in signalling, rolling stock and fixed installations.
What we like:
The VariTrans P 43000 D2 Direct connected AC/DC Current Input Transducers have been specially designed for measurements within high voltage systems. They reliably isolate high potentials at the input circuit. The separation distances are designed to withstand permanent voltages up to 2.2kV AC/DC and fast transients up to 13.5kV. Protection against electric shock is achieved through protective separation according to EN 61140 between input and output and power supply.
There are 5 selectable DC current input ranges and 3 output signal combinations to choose from. (With others available on request)